Product Description
Technical Parameters
â– Display Format: LCD
â– Back light: LED
â– SPO2:35-99%
â– Pulse Ratio:30-250 BPM
â– Pulse Wave: LCD Graphic Display
â– Battery Voltage Low Indication: LCD signals.
â– Power Requirements: Two AA size 1.5V Alkali Battery;
â– Power Consumption: less than 20 mA.
â– Resolution: ?1% for SPO2 and ?1 BPM for Pulse Ratio.
â– Measurement Accuracy: ?2% in stage of 70%-99% SPO2 and meaningless when stage being smaller than 70%. ?2BPM for Pulse Ratio.
■Measurement Performance in Weak Filling Condition : Oxyhemoglobin and pulse &#118alue can be shown correctly when pulse-filling ratio is 0.4%.
■Interference Resistance Capacity against Ambient Light : Deviation is smaller than ?1% between &#118alue of Oxyhemoglobin measured in natural lighting indoor condition and present lighting sources and that measured in dark room.
â– It is equipped with a function switch, hrough which the Oximeter can be automatically powered off when no finger is in the Oximeter more than 8 seconds.
Price Terms︰ FOB Beijing
Payment Terms︰ T/T
Standards Certificate︰ CE FDA
Way for payment︰ Paypal , Bank wire transfer
Finger pulse oximeter cms50D
Product Description
Technical Parameters
â– Display Format: LCD
â– Back light: LED
â– SPO2:35-99%
â– Pulse Ratio:30-250 BPM
â– Pulse Wave: LCD Graphic Display
â– Battery Voltage Low Indication: LCD signals.
â– Power Requirements: Two AA size 1.5V Alkali Battery;
â– Power Consumption: less than 20 mA.
■Resolution: ±1% for SPO2 and ±1 BPM for Pulse Ratio.
■Measurement Accuracy: ±2% in stage of 70%-99% SPO2 and meaningless when stage being smaller than 70%. ±2BPM for Pulse Ratio.
■Measurement Performance in Weak Filling Condition : Oxyhemoglobin and pulse &#118alue can be shown correctly when pulse-filling ratio is 0.4%.
■Interference Resistance Capacity against Ambient Light : Deviation is smaller than ±1% between &#118alue of Oxyhemoglobin measured in natural lighting indoor condition and present lighting sources and that measured in dark room.
â– It is equipped with a function switch, hrough which the Oximeter can be automatically powered off when no finger is in the Oximeter more than 8 seconds.